What is an Air Handling Unit (AHU)?

An air handling unit – commonly shortened to AHU – is a unit which regulate and circulate indoor air. Central elements in an AHU are the fan and the heating, cooling or combi-coil. An AHU provides air treatment according to temperature, humidity and quality requirements and blows the air into a specific room or into the duct system. This handling process will flow air by the waterborne coil(s) providing the proper air temperature and with that also room temperature. AHUs are generally servicing larger areas and thereby larger flow rates.

 

How is an Air Handling Unit (AHU) Application Optimized?

An efficient AHU will - with proper balance - significantly reduce energy consumption, operating costs and help increase the building’s overall energy performance. FlowCon recommends three different solutions to an AHU installation:

  1. Pressure Independent Control (PICV)
  2. Pressure Independent and Temperature Control (PITCV)
  3. Automatic Balancing (ABV or Flow Limiter)

1. Air Handling Units with Pressure Independent Control (PICV)

The PICV will react to system pressure changes and regulate the flow of water to required flow by adjusting the actuator position. This helps the system to be accurately controlled even with pressure changes and reduced loads.

 

→ Download Application Drawing Example

 

FlowCon recommends the following PICVs:

2. Air Handling Units with Pressure Independent and Temperature Control (PITCV)

The PITCV will react only to change in ΔT, which can be either deliberately set to a new target or automatic due to occupancy change. The PICV actuator will only move if a ΔT change is sensed. By optimizing ΔT, flow may be reduced to a minimum resulting in significant energy savings and extended life of equipment, while providing pressure independent ΔT control and optimized comfort. 

 

→ Download Application Drawing Example

 

FlowCon recommends the following PITCV:

3. Air Handling Units with Automatic Balancing (ABV)

The automatic balancing valve will react to system pressure changes and limit the flow of hot or cold water to required max. flow helping the system to be accurately controlled even with pressure changes. This solution is recommended to be installed with the separate control valve.

 

→ Download Application Drawing Example

 

FlowCon recommends the following ABVs:

Some FlowCon Projects with Air Handling Units

See all projects

Cooling - Air handling units - FlowCon Green - FlowCon SM

New recreational facilities including opening of the world's longest air-conditioned outdoor walking track open the possibility of a healthier…

Cooling - Air handling units - Pre-Cool Air Handling Units - Fan Coil Units - FlowCon Green - FlowCon SM

800 well-known international and domestic brands under one roof, and indoor climate is controlled by FlowCon valves

FlowCon Project at Zhenru Sub Center in Shanghai
Heating - Cooling - Air handling units - Fan Coil Units - FlowCon Green - FlowCon SM - FlowCon DRJT - FlowCon Wafer

The super high-rise corner stone includes FlowCon PICVs, DPCVs and ABVs

FlowCon Project at Kuwait SOCS University
Heating - Cooling - Air handling units - Heat Recovery Units - FlowCon SM

High level education and high level of temperature control united with FlowCon PICVs – running optimal year in and year out

FlowCon Project at Hangzhou Xiaoshan International Airport in China
Heating - Cooling - Air handling units - Fan Coil Units - FlowCon Green - FlowCon SM - FlowCon EDP - FlowCon FYC - FlowCon EVS

Huge project providing double terminal area to handle triple number of air travelers

FlowCon Project at Colombo City Centre
Cooling - Air handling units - Chillers - Condensers - Fan Coil Units - FlowCon EVS - FlowCon Green - FlowCon SM - FlowCon Wafer

Mixed-use complex with apartments, hotel, shopping mall and entertainment

Still in Doubt?
Please Contact Us

If You are in doubt which Solution to choose to Your Application or how a specific product is working, please do not hesitate contacting FlowCon.

We will react as soon as possible, and written reply is normally within 8 hours if Your question is asked in English and during office hours. Other languages and requests asked during vacation time or weekends may experience longer response time. Likewise, for any special and out of standard requests, You may not see an immediate reply, but we are responsive.

Contact us here →